Win8.1啟動(dòng)不了BITS服務(wù)錯(cuò)誤1075的應(yīng)對(duì)措施
有用戶反映在使用Win8.1系統(tǒng)時(shí)會(huì)遇到關(guān)于BITS服務(wù)的問題。在操作系統(tǒng)的過程中出現(xiàn)”Windows無法啟動(dòng)Background Intelligent Transfer Service服務(wù)(位于本地計(jì)算機(jī)上)。錯(cuò)誤1075:服務(wù)不存在,或已被標(biāo)記為刪除“的提示。那么要怎么解決此問題呢?
無法啟動(dòng)BITS服務(wù)解決方法如下:
1、在桌面新建一個(gè)文本文檔。
2、將以下代碼復(fù)制粘貼到文本文檔中。
Windows Registry Editor Version 5.00
[HKEY_LOCAL_MACHINE/SYSTEM/CurrentControlSet/services/EventSystem]
“DisplayName”=“@comres.dll,-2450”
“ImagePath”=hex(2):25,00,53,00,79,00,73,00,74,00,65,00,6d,00,52,00,6f,00,6f,00,/
74,00,25,00,5c,00,73,00,79,00,73,00,74,00,65,00,6d,00,33,00,32,00,5c,00,73,/
00,76,00,63,00,68,00,6f,00,73,00,74,00,2e,00,65,00,78,00,65,00,20,00,2d,00,/
6b,00,20,00,4c,00,6f,00,63,00,61,00,6c,00,53,00,65,00,72,00,76,00,69,00,63,/
00,65,00,00,00
“Description”=“@comres.dll,-2451”
“ObjectName”=“NT AUTHORITY//LocalService”
“ErrorControl”=dword:00000001
“Start”=dword:00000002
“Type”=dword:00000020
“DependOnService”=hex(7):72,00,70,00,63,00,73,00,73,00,00,00,00,00
“ServiceSidType”=dword:00000001
“RequiredPrivileges”=hex(7):53,00,65,00,43,00,68,00,61,00,6e,00,67,00,65,00,4e,/
00,6f,00,74,00,69,00,66,00,79,00,50,00,72,00,69,00,76,00,69,00,6c,00,65,00,/
67,00,65,00,00,00,53,00,65,00,49,00,6d,00,70,00,65,00,72,00,73,00,6f,00,6e,/
00,61,00,74,00,65,00,50,00,72,00,69,00,76,00,69,00,6c,00,65,00,67,00,65,00,/
00,00,00,00
“FailureActions”=hex:80,51,01,00,00,00,00,00,00,00,00,00,03,00,00,00,14,00,00,/
00,01,00,00,00,e8,03,00,00,01,00,00,00,88,13,00,00,00,00,00,00,00,00,00,00
[HKEY_LOCAL_MACHINE/SYSTEM/CurrentControlSet/services/EventSystem/Parameters]
“ServiceDll”=hex(2):25,00,73,00,79,00,73,00,74,00,65,00,6d,00,72,00,6f,00,6f,/
00,74,00,25,00,5c,00,73,00,79,00,73,00,74,00,65,00,6d,00,33,00,32,00,5c,00,/
65,00,73,00,2e,00,64,00,6c,00,6c,00,00,00
“ServiceDllUnLoadOnStop”=dword:00000001
3、點(diǎn)擊文件—另存為,輸入文件名“BITS.reg”,保存類型為“所有文件”,點(diǎn)擊保存。
4、雙擊BITS.reg文件,或者右鍵選擇“以管理員身份運(yùn)行”,導(dǎo)入注冊(cè)表。
5、重啟系統(tǒng),就能啟動(dòng)BITS服務(wù)了。
上述就是在Win8.1系統(tǒng)中啟動(dòng)不了BITS服務(wù)錯(cuò)誤1075的應(yīng)對(duì)措施,因?yàn)閃indows更新會(huì)依賴于BITS服務(wù),所以用戶如遇此問題要盡快解決。
相關(guān)文章:
1. Windows Vista操作系統(tǒng)磁盤整理全面解析2. Windows操作系統(tǒng)中IPVv6安全性的思考3. Windows8應(yīng)用商店打不開的修復(fù)措施4. Win10怎么啟用隱藏受保護(hù)的操作系統(tǒng)文件?5. 如何安裝Windows Me操作系統(tǒng)?6. 體驗(yàn)Windows Vista操作系統(tǒng)搜索功能7. Windows8.1寬帶連接出現(xiàn)錯(cuò)誤651如何解決8. Windows XP操作系統(tǒng)鏡像制作技巧大放送9. Windows操作系統(tǒng)圖形化維護(hù)全攻略10. Windows XP操作系統(tǒng)中輕松查找MAC地址